Overview

Advanced technology. Innovative design. Exceptional performance.

Designed for use with any bed , the Stand-alone Resuscitation* System brings life-saving capabilities virtually anywhere . The streamlined design puts integrated features at your fingertips for effective airway management, gentle ventilation and accurate pulse oximetry. Your entire team will enjoy quick, convenient and unobstructed access to all components and capabilities.

Benefits

Enjoy advanced solutions for quickly and safely delivering neonatal resuscitation therapy to your precious, high-risk newborns:

Effective, reliable airway management

  • Fully integrated, gas-powered suction device is built in to help you quickly clear the airway. 

  • Suction canister holder accommodates various sizes and is easily accessible for single-patient use. 

Gentle breathing stimulation
Gentle ventilation to stimulate breathing

  • Dual flow meter design helps you deliver consistent flow. 

  • O2 blender allows you to easily change oxygen concentrations from 21% to 100%. 

Available exclusively on Bag-mask andthe T-Piece Resuscitation System:

Precise and controlled Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP)

  • Essential for adequate oxygenation and Functional Residual Capacity

  • Set prior to resuscitation, the desired levels are maintained automatically throughout the procedure

User-frlendly PIP safety valve

  • Easily activated with just one hand

  • Adjust to 30 cmH2O without interrupting the procedure

  • Easily adjust to 45 cmH2O to help ensure maximum pressure isn’t exceeded

Technology

Get exceptional performance every time:

  • Consistent performance: Clinician’s bag @ 20/5 x 40 bpm

Manual Bag & Mask vs. T-Piece:
These results demonstrate that when used properly, T-Piece style resuscitation may provide for more consistent pressure delivery compared to manual self- or flow-inflating resuscitator bags.1

  • Faster pressure adjustment: Transition time from 20 to 40 cmH2O

Resuscitation system performance
The design of GE Healthcare resuscitation systems eases adjustment of maximum inspiratory pressure to speed transition to the desired pressure level.

  • Improved performance: ~3x faster transition from 20 to 40 cmH2O

Resuscitation T-Piece performance
The improved transition time for adjustment of the T-Piece system results in an approximately three-times faster transition to desired pressure and correspondingly fewer breaths within the transition time.

  1. Bennett, S.; Finer, N.N.; Rich, W., and Vaucher, Y. A comparison of three neonatal resuscitation devices. Resuscitation. 67 (2005): 113-8.

  2. Finer, N.N.; Rich, W.; and Craft, A.; and Henderson, C. Comparison of bag and mask ventilation for neonatal resuscitation. Resuscitation. 49 (2001): 299-305. 3 Lynam, L.; Boyd, L.C., and Tsitlik. A. Bench evaluation of a novel T-Piece Resuscitation System design. Abstract, GE Healthcare, 2007. 

Specifications

Technical Specifications for Stand-alone Resuscitation* Systems

Environmental specifications
Operating temperature 18° to 41°C
Operating humidity 0 to 90%
Storage temperature -25° to 60°C
Storage humidity 0 to 95%
Storage pressure 50 to 106 kPa

Physical characteristics
Depth (knobs to fittings) <8.7 in (22 cm)
Height <14.6 in (37 cm)
Width <11.8 in (30 cm)
Weight Approx. 15 lbs (7 Kg)

System characteristics
Input source Hospital pipeline or cylinder
Input pressure (Air/O2 fittings) 40-75 psi (275-517 kPa)
Minimum input 70 lpm
Vacuum range 0-150 mm Hg
Vacuum accuracy ± 5% of full scale
Flow capacity 15 lpm
Flow range 0-15lpm
Flow accuracy –5 lpm ±0.51⁄2 lpm
5-10 lpm ±1.5 lpm
10-15 lpm ±2 lpm

Airway pressure manometer
Range –10 to 80 cmH2O
Accuracy ±5% of full scale

Air/O2 blender
Range 21-100% O2
Accuracy ±5%O2 of full scale

User control settings
Air/O2 flow meter set range 0-15 lpm
Suction regulator set range 0–150 mmHg

Recommended body weight range
Up to 22 lbs (10 kg)

For T-Piece Resuscitation System only

Adjustable PIP range

(located on the resuscitation front panel)
Maximum PIP: 45 ±5 cmH2O
Override: >30 ±4 cmH2O

Adjustable PEEP range
(located on the T-Piece circuit )
@ 5 L/min minimum PEEP <5 cmH2O
@ 8 L/min minimum PEEP <5 cmH2O
@ 10 L/min minimum PEEP <5 cmH2O
@ 15 L/min minimum PEEP <6 cmH2O


Related